  • Having techniques available for the accurate quantification of potential CO2 surface leaks from geological storage sites is critical for regulators, public assurance and for underpinning carbon pricing mechanisms. Currently, there are few options available that enable accurate CO2 quantification of potential leaks at the soil-atmosphere interface. Integrated soil flux measurements can be used to quantify CO2 emission rates from the soil and atmospheric techniques such as eddy covariance or Lagrangian stochastic modelling have been used with some success to quantify CO2 emissions into the atmosphere from simulated surface leaks. The error for all of these techniques for determining the emission rate is not less than 10%. A new technique to quantify CO2 emissions was trialled at the CO2CRC Ginninderra controlled release site in Canberra. The technique, termed atmospheric tomography, used an array of sampling sites and a Bayesian inversion technique to simultaneously solve for the location and magnitude of a simulated CO2 leak. The technique requires knowledge of concentration enhancement downwind of the source and the normalized, three-dimensional distribution (shape) of concentration in the dispersion plume. Continuous measurements of turbulent wind and temperature statistics were used to model the dispersion plume.

  • Covering an area of approximately 247 000km2, the Galilee Basin is a significant feature of central Queensland. Three main depocentres contain several hundred metres of Late Carboniferous to Middle Triassic sediments. Sedimentation in the Galilee Basin was dominated by fluvial to lacustrine depositional systems. This resulted in a sequence of sandstones, mudstones, siltstones, coals and minor tuff in what was a relatively shallow intracratonic basin with little topographic relief. Forty years or more of exploration in the Galilee Basin has failed to discover any economic accumulations of hydrocarbons, despite the presence of apparently fair to very good reservoirs and seals in both the Permian and Triassic sequence. Despite some relatively large distances (upwards of 500km) between sources and sinks, previous and ongoing work on the Galilee Basin suggests that it has potential to sequester a significant amount of Queensland's carbon dioxide emissions. Potential reservoirs include the Early Permian Aramac Coal Measures, the Late Permian Colinlea Sandstone and the Middle Triassic Clematis Sandstone. These are sealed by several intraformational and local seals as well as the regional Triassic Moolayember Formation. With few suitable structural traps and little faulting throughout the Galilee sequence, residual trapping within saline reservoir is the most likely mechanism for storing CO2. The current study is aimed at building a sound geological model of the basin through activities such as detailed mapping, well correlation, and reservoir and seal analysis leading to reservoir simulations to gain a better understanding of the basin.

  • This animation has been developed by Geoscience Australia to illustrate the carbon dioxide capture, transportation and storage process. Carbon capture and storage (CCS) is one of the technologies that we can use to reduce greenhouse gas emissions to the atmosphere, particularly from sources such as coal or natural gas fired power stations and industrial plants. In this process carbon dioxide (CO2) is captured at the source (e.g. power station), transported via pipeline and injected deep underground into a porous rock, such as sandstone. There it is trapped by the overlying fine grained and impermeable mud rocks.

  • No abstract available

  • Many industries and researchers have been examining ways of substantially reducing greenhouse gas emissions. No single method is likely to be a panacea, however some options do show considerable promise. Geological sequestration is one option that utilises mature technology and has the potential to sequester large volumes of CO2. In Australia geological sequestration has been the subject of research for the last 2? years within the Australian Petroleum Cooperative Research Centre's GEODISC program. A portfolio of potential geological sequestration sites (?sinks?) has been identified across all sedimentary basins in Australia, and these have been compared with nearby known or potential CO2 emission sources. These sources have been identified by incorporating detailed analysis of the national greenhouse gas emission databases with other publicly available data, a process that resulted in recognition of eight regional emission nodes. An earlier generic economic model for geological sequestration in Australia has been updated to accommodate the changes arising from this process of ?source to sink? matching. Preliminary findings have established the relative attractiveness of potential injection sites through a ranking approach. It includes the ability to accommodate the volumes of sequesterable greenhouse gas emissions predicted for the adjacent region, the costs involved in transport, sequestration and ongoing operations, and a variety of technical geological risks. Some nodes with high volumes of emissions and low sequestration costs clearly appear to be suitable, whilst others with technical and economic issues appear to be problematic. This assessment may require further refinement once findings are completed from the GEODISC site-specific research currently underway.

  • Approximately one quarter of Australia's CO2 emissions come from southeast and central Queensland. This poster presents the geoscientific interpretations which lead to constructing a simplified 3-D model of a potential geological storage site for CO2. The Bowen Basin is located in northeast Australia, approximately 200 to 500 km from major CO2 emission hubs in southeast Queensland. The resources of the Bowen Basin include coal, oil and gas, and there are water resources within the overlying Great Artesian Basin. Defining trap integrity within the Bowen Basin is important to ensure that none of these resources are compromised. The Wunger Ridge area has been the focus of petroleum exploration for hydrocarbons. Geological, geophysical, hydrodynamic, petrological, petrophysical and seal capacity interpretations of datasets from the area were undertaken. These interpretations indicate that the Triassic fluvial - deltaic Showgrounds Sandstone is the most suitable for CO2 storage and injection as it is permeable and saturated with brackish to saline water except where hydrocarbons have accumulated. Geological profiles were developed using sequence stratigraphic concepts and combined with rock properties, measured from core, to produce simplified 3-D models with the goal of assessing parameters for CO2 injection and migration. Simulation runs using simple models, based on a coarse-scale grid, suggest that either one horizontal or two vertical wells are required to inject at the proposed rate. Geological heterogeneity increases injection pressure around the wellbore and reduces injection rates compared to homogeneous models, resulting in the need for more injection wells.

  • Eddy Covariance (EC) is considered a key atmospheric technique for quantifying CO2 leakage. However the complex and localised heterogeneity of a CO2 leak above the background environmental signal violates several of the critical assumptions made when implementing the EC technique, including: - That horizontal gradients in CO2 concentration are zero. - That horizontal and vertical gradients in the covariance of CO2 and orthogonal wind directions are zero. The ability of EC measurements of CO2 flux at the surface to provide information on the location and strength of CO2 leakage from below ground stores was tested during a 144 kg/day release event (27 March - 13 June 2012) at the Ginninderra controlled release facility. We show that the direction of the leak can be ascertained with some confidence although this depends on leak strength and distance from leak. Elevated CO2 levels are seen in the direction of the leakage area, however quantifying the emissions is confounded by the potential bias within each measurement through breaching of the assumptions underpinning the EC technique. The CO2 flux due to advection of the horizontal CO2 concentration gradients, thought to be the largest component of the error with the violation of the EC technique's assumptions, has been estimated using the modelling software Windtrax. The magnitude of the CO2 flux due to advection is then compared with the measured CO2 flux measured using the EC technique, to provide an initial assessment of the suitability of the EC technique to quantifying leakage source rates.

  • Geological storage of greenhouse gases is one approach that the Australian Government is pursuing to assist Australia, and the world, to reduce greenhouse gas emissions into the atmosphere. Understanding the geology of Australia's sedimentary basins and their potential for greenhouse gas storage is an important component of Geoscience Australia's work in supporting emission reductions.

  • A shallow vertical CO2 injection test was conducted over a 21 day period at the Ginninderra Controlled Release Facility in May 2011. The objective of this test was to determine the extent of lateral CO2 dispersion, breakthrough times and permeability of the soil present at the Ginninderra site. The facility is located in Canberra on the CSIRO agricultural Ginninderra Experiment Station. A 2.15m deep, 15cm stainless steel screened, soil gas sampling well was installed at the site and this was used as the CO2 injection well. The CO2 flow rate was 1.6 L/min (STP). CO2 soil effluxes (respiration and seepage) were measured continuously using a LICOR LI-8100A Automated Soil CO2 Flux System equipped with 5 accumulation chambers spaced 1m apart in a radial pattern from the injection well. These measurements were supplemented with CO2 flux spot measurements using a WestSystems portable fluxmeter. Breakthrough at 1m from the injection point occurred within 6 hrs of injection, 32hrs at 2m and after almost 5 days at 3m. The average steady state CO2 efflux was 85 ?mol/m2/s at 1m, 15 ?mol/m2/s at 2m and 5.0 ?mol/m2/s at 3m. The average background CO2 soil respiration efflux was 1.1 - 0.6 ?mol/m2/s. Under windy conditions, higher soil CO2 efflux could be expected due to pressure pumping but this is contrary to the observed results. Prolonged windy periods led to a reduction in the CO2 efflux, up to 30% lower than the typical steady state value.

  • CO2CRC Project 1 - Site Specific Studies for Geological Storage of carbon Dioxide Part 1: Southeast Queensland CO2 Storage Sites - Basin Desk-top, Geological Interpretation and Reservoir Simulation of Regional Model